Canteens & Dining Rooms
The lighting in the canteen areas should be inviting and comfortable yet at the same time provide the required illuminance for the high level of activity.
Choice of Luminaire
The lighting should provide a relaxed atmosphere with enough light for the high volume of people. If the space is multi-use then suitable luminaires should be used.
G3 recessed downlighters provide uniform illumination whilst maintaining a clean ceiling appearance.
Heritage pendants over serveries look good, and help create a relaxed, informal atmosphere.
Illumination Levels
Extract from CIBSE: SLL Lighting Guide 5 - Lighting for Education 2011
Application | Maintained Horizontal Illuminance (lux) | UGRL | U0 | Ra |
---|---|---|---|---|
Canteens - general | 200 | 22 | 0.4 | 80 |
If used for exams | 500 | 19 | 0.6 | 80 |
SmartScan Lighting Management
SmartScan controls can be used to adjust the lighting level for each activity. The wireless communication between luminaires is ideal for suspended applications as no additional wiring is required.
More DetailsEmergency Lighting
Emergency lighting is recommended for rooms larger than 60 m². BS 5266-1 recommends a minimum illumination level of 0.5 lux